Share

Raised and Lowered M.E. Hercules Brackets: managing level discrepancies during erection

During the erection of precast concrete elements, the actual level of the bearing point may not coincide with the level specified in the design.

The critical condition arises when the Tube Box and Screw Box have already been embedded in their respective elements and, during erection, the joint geometry reveals a difference between the design level and the level actually achieved.

Under these conditions, it is not simply a matter of using the normal millimetric adjustment of the M.E. Hercules Bracket. The system must maintain its support configuration while adapting to a different starting level.

For this specific requirement, B.S. Italia provides the M.E. Raised and M.E. Lowered versions, available upon request and developed to correct possible level errors between design and construction. These are variants of the M.E. Hercules Bracket intended to manage discrepancies generated during production of the precast elements.

Table of contents

Level discrepancies and millimetric adjustment are not the same thing

The standard M.E. Hercules Bracket allows the bearing level, projection and centre-to-centre position of the precast element to be adjusted during erection.

This adjustability is part of the normal operation of the system and is intended for precise control of panel positioning during erection, with millimetric adjustment along the three Cartesian axes.

The Raised and Lowered versions address a different condition.

They are intended for use when the as-built geometry presents a difference in level compared with the design and the standard M.E. Bracket must be replaced with a variant having a different geometric configuration.

They are therefore not simply an extension of the normal screw adjustment. The correction is achieved by changing the geometric position of the bracket bearing point compared with the standard configuration.

This distinction is important when checking the joint: millimetric adjustment is used to position the element precisely during erection, while M.E. Raised and M.E. Lowered are used when the starting level of the connection differs from the specified level.

M.E. Raised when the bearing point must be brought to a higher level

The M.E. Raised Hercules Bracket is used in place of the M.E. Bracket in the event of production errors.

Compared with the standard configuration, the geometry of the bracket brings the bearing point to a higher level while maintaining integration with the Tube Box and Screw Box of the Ercole system.

The correction is therefore not achieved by modifying the Tube Box on site or by altering components already embedded in the concrete.

It is the bracket, the free and removable component of the system, that has a different geometry from the standard M.E.

The construction principle of the system remains unchanged:

  • Tube Box embedded in the structure;
  • free and removable bracket inserted during erection;
  • Screw Box installed in the panel.

The possibility of using a bracket with raised geometry therefore allows the correction to be concentrated on the component installed during erection, without altering the elements already embedded during casting.

M.E. Lowered when the bearing level must be reduced

The M.E. Lowered Hercules Bracket addresses the opposite condition.

This variant is also used in place of the M.E. Bracket where production errors are present, but its geometry brings the bearing point to a lower level than the standard configuration.

In the M.E. Lowered configuration, the lowered part of the bracket must remain in contact with the structure.

This requirement must be considered when checking the actual geometry of the joint. The variant cannot be treated as a simple interchangeable component independently of the actual bearing conditions.

Once the discrepancy has been identified, the configuration must therefore be defined in relation to the actual position of the Tube Box, the panel level and the geometric relationship between the bracket and the structure.

The correction concerns the bracket, not the inserts already embedded

One of the characteristic aspects of the Raised and Lowered versions derives from the configuration of the Ercole system itself.

In the internal version, the Tube Box forms the load-bearing component embedded in the structure, while the Screw Box is embedded in the panel. The bracket remains a free, removable and adjustable component.

When the discrepancy is detected after the precast elements have been produced, the Tube Box and Screw Box are already embedded in the concrete.

The M.E. Raised and M.E. Lowered versions therefore make it possible to act on the removable component of the system through a specific geometry, without arbitrarily modifying the inserts already embedded in the precast elements.

Modifications to components that may result in changes to their technical characteristics or working conditions are not permitted unless expressly authorised.

Management of the discrepancy therefore remains within a configuration provided by the Ercole system.

The Tube Box remains the one specified for the M.E.

M.E. Raised and M.E. Lowered belong to the internal Hercules Bracket family and retain the connection with the Tube Box specified for the M.E.

The S.T. Tube Box and semi-reinforced S.T. can also be used with M.E. Raised and M.E. Lowered.

Correcting the level therefore does not introduce a different principle for connecting the system to the structure.

The Tube Box already installed must still comply with the conditions specified by the system in terms of position, reinforcement and element configuration.

The bracket variant corrects the bearing geometry but does not replace correct design and installation of the inserts embedded in the concrete.

The Screw Box must also remain compatible with the configuration

On the panel side, M.E. Raised and M.E. Lowered can be combined with the Screw Boxes specified for the Ercole system.

The S.V. Screw Box and the S.V.T. and S.V.S. versions can be used.

For panels less than 16 cm thick, Raised and Lowered brackets may only be used with S.V.T. or S.V.S. Screw Boxes; in this configuration, the panel is spaced from the structure.

Even when the objective is to correct a level detected during erection, the solution must therefore be checked by considering the complete system configuration and not the bracket alone.

From on-site verification to selection of the variant

Managing the discrepancy starts with a survey of the geometry actually constructed.

Before defining an M.E. Raised or Lowered configuration, the relationship between the following must be checked:

  • position of the Tube Box in the structure;
  • position of the Screw Box in the panel;
  • specified bearing level;
  • actual level achieved;
  • panel thickness;
  • configuration and load capacity of the Ercole system used.

These data determine the choice between a raised configuration and a lowered configuration.

The correction therefore does not consist of directly adapting the existing components on site, but of identifying the Hercules Bracket variant that is consistent with the geometry actually achieved.

Selection of the component must in any case be related to the application and the actions involved.

Load capacity and structural function remain defined by the Ercole system

The geometric variation of the bracket does not change the fundamental structural function of the system.

M.E. Raised and Lowered are available in 2, 5, 7.5, 10 and 15 tonne versions.

Like the other Hercules Brackets, the Raised and Lowered versions are also designed to support vertical loads and must not be used to apply horizontal actions.

The need to correct a level discrepancy must therefore not lead to the variant being assigned a function other than that intended for the support system.

Selection must continue to be related to the required load capacity, the element configuration and the actual connection conditions.

Correcting the level while maintaining the Ercole system configuration

Geometric discrepancies may only become apparent when the precast elements are brought into their intended position and have to be connected.

At that stage, however, the main inserts are already embedded in the concrete and cannot be regarded as freely repositionable components.

M.E. Raised and M.E. Lowered are specifically intended for this condition: they are dedicated variants of the M.E. Hercules Bracket, available upon request, which allow level errors between design and construction to be managed through a different geometry of the removable component.

The Tube Box, Screw Box and bracket therefore continue to form a coordinated assembly. What changes is the geometric configuration of the bracket used to complete the joint.

The discrepancy is therefore addressed using a component specifically provided within the B.S. Italia system, avoiding improvised adaptations or modifications to elements already integrated into the precast element.

Learn more about the support systems for precast elements developed by B.S. Italia.

Frequently asked questions about Raised and Lowered Hercules Brackets

When is M.E. Raised used?

M.E. Raised is used in place of the M.E. Bracket in the event of production errors, when a raised level compared with the standard configuration is required.

When is M.E. Lowered used?

M.E. Lowered is used in place of the M.E. Bracket in the event of production errors, adopting a lowered level compared with the standard configuration.

Do the Raised and Lowered versions replace the millimetric adjustment of the Hercules Bracket?

No. Millimetric adjustment is part of the normal operation of the Ercole system. The Raised and Lowered versions are instead specific configurations intended to correct level errors between design and construction.

Which Screw Boxes can be used with M.E. Raised and M.E. Lowered?

M.E. Raised and M.E. Lowered can be used with the S.V., S.V.T. and S.V.S. Screw Boxes. For panels less than 16 cm thick, S.V.T. or S.V.S. must be used; in this case, the panel is spaced from the structure.

Related Articles
Write us for information